Quotation

Bottle Sampling

110ML

110ml standard bottle sampler unit incorporates de-aeration facility.

Suitable for mineral oil applications only.

250ML

250ml laboratory bottle sampler unit incorporates de-aeration facility.

See Ordering Information for part numbers for phosphate esters and mineral oil applications.

View of a 110ml bottle sampler unit

A simple selection of the correct switch will enable the user to choose between VACUUM and de-aeration or SAMPLE to carry out analysis of the bottle sample.

 
Air can be seen as contaminants

An example of the difference between an aerated sample and non aerated sample can be seen below.

CERTIFICATE OF CLEANLINESS

MP Filtri UK hereby confirms that the sample bottles provided, Part No: .P.02, have been cleaned in accordance with
DIN/ISO 5884.

The degree of cleanliness has been verified to ISO 3722 with a NAS 1638 cleanliness certification of between Class 00 and
Class 0.


< select buttons for further information
CLEAN BOTTLES
[ From BFPA/P5 report on Sample Bottles Cleanliness]

It is essential that only sample bottles which have been cleaned and verified by the ISO 3722 standard are used. Modern hydraulic systems featuring highly effective filters have fluid cleanliness levels that approach that of the sample bottles themselves.The use of uncleaned bottles can greatly increase the particle counts (see table below). Please note that sterilisation kills bacteria but does not remove particles. Perhaps of even greater concern is the variability in their levels; some may be reasonably clean and give a fair representation of the system's cleanliness, only to experience a sudden increase in contamination when unknowingly a dirty bottle is used. This apparent increase could instigate unnecessary corrective action.
Sample Particle Counts per 100mL
 
>2 µm
>5 µm
> 15 µm
> 25 µm
> 50 µm
Bottles
250mL bottles cleaned to ISO 3772
As received (glass)

As received (plastic)

System Levels
Servo controlled fatigue rig
Plastic injection moulding machines
Agricultural tractors (roll-off) cleanliness

Rail car transmissions

285
5,900
10,150


4,200
7,160
-
12.600

150
3,480
6,615


2,268
2,900
14,200
5,650

26
1,090
2,410


640
784
804
760

7
4 25
1,115


183
192
308
121

0
102
275


24
16
24
6
Table : Cleanliness of sample bottles compared to system levels
Sampling Methods
ENG
FRE
Moisture Sensor

 

Home
Bottle sampling options
bottle-sampling-options
Accessories
accessories
LPA2 Features + benefits
lpa2-features-and-benefits
PML2 Features + benefits
pml2-features-and-benefits
Re-calibration
re-calibration
Software
software
Testimonials + Reviews
testimonials
LPA2 Ordering information
lpa2-ordering-information
PML2 Ordering information
pml2-ordering-information
CML2 Ordering information
Manuals + brochures
manual-and-brochures
Technical standards
Technical information
CONTACT >
contact-button
Exhibition dates
Company Profile